0 item(s) - €0.00

Recently added item(s)

You have no items in your shopping cart.
Compare 0 item(s)
You have no items to compare.
  1. Home
  2. POWERCOM UPS VGD-3000RM (2U) ON-LINE
POWERCOM UPS VGD-3000RM (2U) ON-LINE

POWERCOM UPS VGD-3000RM (2U) ON-LINE

Excl. Tax: €1,046.22 Incl. Tax: €1,245.00

In stock

POWERCOM UPS VGD-3000RM (2U) ON-LINE
QR Code:

Details

GENERAL INFORMATION

  • Model Type| VANGUARD RM
  • Model Name| VGD-3000RM

AC INPUT

  • AC Input Capacity on Battery | 3000VA
  • AC Input Voltage| 100V or 110V/120V/127V or 208V/220V/230V/240V
  • AC Input Frequency |50/60 Hz +/-0.5%

AC OUTPUT

  • AC Output Waveform Sinewave
  • AC Output Voltage 100V or 110V/120V/127V or 208V/220V/230V/240V +/-2%
  • AC Output Frequency 50/60 Hz +/-0.5%
  • AC Output Transfer 0 ms
  • AC Output Efficiency >95%
  • AC Output Hamonic distortion <3% of T.H.D. at linear load
  • AC Output Crest factor ratio 3 : 1

PROTECTION

  • Protection Spike 1015 Joules
  • Protection Surge Protection 120V (IEEE C62.41) / 230V (IEEE C61000-4-5 level 3)
  • Protection Overload Protection 125% for 1 minutes and 150% for 10 seconds
  • Protection Short Circuit UPS output cut off immediately or input fuse/circuit breaker protection

BATTERY

  • Battery Type |sealed, maintenance-free lead acid batteries
  • Battery Typical |Recharge time to 90% full: 4 hours
  • Battery Protection |cut off without draining any current when battery is low

BACKUP TIME

  • Battery Backup Time Full Load |6 min
  • Battery Backup Time Half Load |15 min

PHYSICAL

  • Physical Weight kgs RM |32.5
  • Physical Weight lbs RM| 71.5
  • Physical Shipping Weight kgs |35.7
  • Physical Shipping Weight lbs| 78.5
  • Physical Dimension mm RM |428x635x84
  • Physical Dimension inch RM |16.9x25.0x3.3
  • Physical Input Inlet NEMA 5-15 |(120V) / IEC 320 (230V)
  • Physical Receptacles NEMA 5-15|(120V) / IEC 320 (230V)


INDICATOR

  • Indicator |LCD Input/output voltage, frequency, on-line mode, back up mode, battery capacity, load level

ALARM

  • Alarm Battery Backup| Beep every 5 sec
  • Alarm UPS Fault |Continuous beeping sound and LCD display

CONFORMANCE

  • Conformance Safety |UL 1778, CE

INTERFACE

  • Interface RS-232| Serial Port & USB
  • Interface Option |SNMP card

ENVIRONMENT

  • Environment Temperature |-20 ~ 50C / -4 ~ 122F
  • Environment Humidity |0 - 95%, non-condensing
  • Environment Operation Temperature |0 - 40C / 32 - 104F
  • Environment Operation Elevation |3500 meters max
  • Warranty|1 Year